- API Reference
- Box API
- Modems
See when and why a modem was stopped or resumed
Use this to explain why a slot is offline. Returns up to 50 latest stop and resume events of the modem now at this position, newest first. status false with an empty list when no modem is at the position.
/v2/modem_stop_historyQuery parameters
Slot number. A non-integer value makes the box answer HTTP 500.
1Authentication
Needs dashboard Basic credentials when dashboard authentication is enabled; trusted callers (loopback, LAN unless "force auth for local" is on, whitelisted IP, allowed Tailscale) pass without them.
Responses
Events.
Internal device id of the modem.
stopped, resumedWho stopped or resumed it, for example web, ip_guard.
Time of the event as stored by the box.
The caller is not trusted (not loopback, LAN, whitelisted or allowed Tailscale) and sent no valid Basic credentials. The body depends on whether "Basic auth for all API" is on. Routes that also use the panel login can answer a plain-text 401 "Unauthorized Access" instead.
Unhandled error, for example a non-integer position or a missing required parameter.
Error name, e.g. internal_server_error or bad_request.