- API Reference
- Box API
- Modems
Clear the stopped state of a modem so it can run again
Use this to undo a stop made by Smart IP Guard or the user. Same effect as POST /v2/connect_dongle (clears the stop, logs resumed, connects the modem) but without the license check. Always answers status true.
/v2/clear_auto_stopRequest body application/json · required
Slot number (position) on the box, starting at 1. A missing or non-integer value makes the box answer HTTP 500.
Authentication
Needs dashboard Basic credentials when dashboard authentication is enabled; trusted callers (loopback, LAN unless "force auth for local" is on, whitelisted IP, allowed Tailscale) pass without them.
Responses
Done.
The caller is not trusted (not loopback, LAN, whitelisted or allowed Tailscale) and sent no valid Basic credentials. The body depends on whether "Basic auth for all API" is on. Routes that also use the panel login can answer a plain-text 401 "Unauthorized Access" instead.
Unhandled error, for example a non-integer position or a missing required parameter.
Error name, e.g. internal_server_error or bad_request.